modbus_tk pip install modbus_tk https://github.com/ljean/modbus-tk pyserial Support modbus TCP and RTU, both master and slave。Don’t support modbus ASCII。 重量级
pymodbus pip install pymodbus https://github.com/riptideio/pymodbus/ pyserial Support modbus TCP/RTU/ASCII, master and slave。 重量级
minimalmodbus pip install minimalmodbus https://github.com/pyhys/minimalmodbus pyserial Only support Modbus RTU and ASCII, and only work in master(clinet). 非常轻量级
uModbus pip install uModbus https://github.com/AdvancedClimateSystems/uModbus/ no Support both Modbus client amd server (both TCP and RTU). Don’t support Modbus ASCII。轻量级

minimalmodbus 使用

Doc:
https://minimalmodbus.readthedocs.io/en/stable/
https://pypi.org/project/minimalmodbus/
API https://minimalmodbus.readthedocs.io/en/stable/apiminimalmodbus.html

read_register (registeraddress, number_of_decimals=0, functioncode=3, signed=False)[source]
Read an integer from one 16-bit register in the slave, possibly scaling it.
The slave register can hold integer values in the range 0 to 65535 (“Unsigned INT16”).
Args:
• registeraddress (int): The slave register address (use decimal numbers, not hex).
• number_of_decimals (int): The number of decimals for content conversion.
• functioncode (int): Modbus function code. Can be 3 or 4.
• signed (bool): Whether the data should be interpreted as unsigned or signed.
Note
The parameter number_of_decimals was named numberOfDecimals before MinimalModbus 1.0
If a value of 77.0 is stored internally in the slave register as 770, then use number_of_decimals=1 which will divide the received data by 10 before returning the value.
Similarly number_of_decimals=2 will divide the received data by 100 before returning the value.
Some manufacturers allow negative values for some registers. Instead of an allowed integer range 0 to 65535, a range -32768 to 32767 is allowed. This is implemented as any received value in the upper range (32768 to 65535) is interpreted as negative value (in the range -32768 to -1).
Use the parameter signed=True if reading from a register that can hold negative values. Then upper range data will be automatically converted into negative return values (two’s complement).
signed Data type in slave Alternative name Range
False Unsigned INT16 Unsigned short 0 to 65535
True INT16 Short -32768 to 32767
Returns:
The register data in numerical value (int or float).
Raises:
TypeError, ValueError, ModbusException, serial.SerialException (inherited from IOError)

write_register (registeraddress, value, number_of_decimals=0, functioncode=16, signed=False)[source]
Write an integer to one 16-bit register in the slave, possibly scaling it.
The slave register can hold integer values in the range 0 to 65535 (“Unsigned INT16”).
Args:
• registeraddress (int): The slave register address (use decimal numbers, not hex).
• value (int or float): The value to store in the slave register (might be scaled before sending).
• number_of_decimals (int): The number of decimals for content conversion.
• functioncode (int): Modbus function code. Can be 6 or 16.
• signed (bool): Whether the data should be interpreted as unsigned or signed.
Note
The parameter number_of_decimals was named numberOfDecimals before MinimalModbus 1.0
To store for example value=77.0, use number_of_decimals=1 if the slave register will hold it as 770 internally. This will multiply value by 10 before sending it to the slave register.
Similarly number_of_decimals=2 will multiply value by 100 before sending it to the slave register.
As the largest number that can be written to a register is 0xFFFF = 65535, the value and number_of_decimals should max be 65535 when combined. So when using number_of_decimals=3 the maximum value is 65.535.
For discussion on negative values, the range and on alternative names, see read_register().
Use the parameter signed=True if writing to a register that can hold negative values. Then negative input will be automatically converted into upper range data (two’s complement).
Returns:
None
Raises:
TypeError, ValueError, ModbusException, serial.SerialException (inherited from IOError)

主流modbus python库比较主流modbus python库比较minimalmodbus 使用主流modbus python库当前,用的比较多的Modbus python 库主要有以下几种:Modbus_tk Pymodbus MinimalmodbusUmodbus比较库名称安装源码3rd party依赖主要功能modbus_tkpip i... 使编写 modbus TCP和RTU主站和从站成为可能。 它可以用于测试目的:它带有从属模拟器和带有基于Web的HMI的主控(好的HMI需要改进:)。 它还可以用于创建需要通过 Modbus 进行通信的任何应用程序。 它是一个全栈实现,用于“实际应用程序”。 得益于 Py thon和令人难以置信的现有库集,它可以满足许多不同的需求:数据库日志记录,HMI,报告生成... modbus - tk py modbus 不同,后者是 py thon中 modbus 堆栈的另一种实现。 modbus - tk 试图限制依赖关系(即使 Modbus RTU需要 py serial)。 modbus - tk tk Inter没有链接。 tk 代表“ tes tk it”或“ too
py thon玩转 modbus 1. modbus 协议简介 Modbus 协议是一项应用层报文传输协议,包括ASCII / RTU / TCP三种报文类型,协议本身不定义物理层,只定义了控制器能够认识和使用的消息结构,而不管消息是经过何种网络进行通信的。 标准的 Modbus 协议物理层接口主要有RS232 / RS422 / RS485和以太网。采用Master/Slave主从方式通信 关于 modbus 协议更多更详细的介绍,可自行查阅 2. 环境配置 py thon 目前 主流 使用操作 modbus 协议的库有三
本文列出了基于 py thon开发的S7/ Modbus /OPCUA/MQTT库: Modbus : Modbus _ tk , Py modbus , Minimal modbus , U modbus MQTT: paho S7: py thon-snap7 OpcUa: py thon-opcua 介绍了安装,使用手册和例子。 具体的用法需要结合使用手册深入学习。 1 modbus 1.1 主流 modbus python库 Modbus _ tk Py modbus Minimal modbus Umo...
JeremyZhong24: [WARN] [1671084188.776373]: Unknown MTi data packet: 'Orientation Data', ignoring. 请问运行节点后一直打印这个警告是为什么 Xsens Mti-g-710 IMU driver在Ubuntu18.04 ROS melodic中的安装使用 o_Oasis: 你好,imu的线带usb,那这根线是购买imu自带的吗?如果不是自带的,有什么渠道可以购买吗?